| Thermal power | 200 | kW |
| Adapted to work with the burner | ZST-180 | |
| The thermal power of the burner ZST | 200 | kW |
| The fuel used | Sawdust and wood chips up to 30 mm, moisture content of 30-50% | |
| Thermal power regulation | 30 – 100 | % |
| Of boiler a heated surface | 18 | m2 |
| Permissible static pressure | 0,25 | MPa |
| Outgoing water temperature max. | 95 | °C |
| Required thrust for the boiler | >2,0 | Pa |
| Recommended temperature of the smoke | 180 – 200 | °C |
| Thermal efficiency factor by using ZST | >=78.7 | % |
| Boiler weight with isolation | 2000 | kg |
| Of water a requirement | l | |
| Length | 1500 | mm |
| Height | 1950 | mm |
| Width | 1200 | mm |
| The output of the the chimney | 350 x 350 | mm |
| Of tubes diameter | DN 65 | mm |